Filtering/QoS Information

[-maxSpecifiesrate<kbps>the maximum[-maxratecontractburstband<Byte>]]restriction by kbit/s. Specifies burst size in byte unit. If a value greater than the line speed is set, no action at breach is taken.

When setting this parameter, it is not possible to set -upc, or -upc_burst.

Packets exceeding the maximum band when setting this parameter are all discarded.

When this is used, the number of entries used per list may become two or four entries.

(This parameter is effective only for RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV, GR2000-1B and GR2000-2B.)

Default:

None. (No contract band surveillance is executed.)

Range of value: <kbps>: 0 to 2400000 (0 to 2.4G) (10-decimals).

If 0 to 11 is specified in the case of RP-A, the operation is performed by taking the contract band as 12[kbps].

If 0 to 4 is specified in the case of RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV, GR2000-1B, GR2000-2B, GR2000-2B+ and GR2000-BH, the operation is performed by taking the contract band as 4.1[kbit/s].

<Byte>: 0 to 131072 (10-decimals)

[-minSpecifiesrate<kbps>the minimum[-minratebandburstassurance<Byte>]]by kbit/s. Specifies burst size in byte unit. If a value greater than the line speed is set, no action at breach is taken.

When setting this parameter, it is not possible to set -upc, or -upc_burst.

When this parameter is used, the number of entries used per list may become two or four entries. (*1)

(This parameter is effective only for RP-C and RP-D.)

Default:

None. (No contract band surveillance is executed.)

Range of value: <kbps>: 0 to 2400000 (0 to 2.4G) (10-decimals).

If 0 to 11 is specified in the case of RP-A, the operation is performed by taking the contract band as 12[kbit/s].

If 0 to 4 is specified in the case of RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV, GR2000-1B, GR2000-2B, GR2000-2B+ and GR2000-BH, the operation is performed by taking the contract band as 4.1[kbit/s].

<Byte>: 0 to 131072 (10-decimals)

[-indexSpecifies<No.the>]connection branching index number (index specified in the DLCI group information or the Ve-Group information). It selects and transmits DLCI/ VC specified in the group when relaying the packet that agrees with the flow detecting conditions. For the list information setting the connection branching index number, specify out (Outbound) as the flow control of the output side.

(This parameter is effective only for RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV, GR2000-1B, GR2000-2B and GR2000-2B+.)

Default: None.

GR2K-GA-0014

1-71

Ver. 07-02

 

Page 113
Image 113
Hitachi GR2000 Series manual Filtering/QoS Information