Message Notification

Unique Programming for Digital Pager Message Notification

1.Set up the system-wide options that apply to the digital pager callback number.

1.In 4202-08: Digital Pager Callback Number (page 877), set the Digital Pager Callback Number portion of the Message Notification callout number for a digital pager.

-This is the portion of the callout number that is appended to the pager service telephone number.

-By default, this option is X*M#, where:

X is the number of the extension that generated the notification.

*is a visual delimiter (to make the pager display easier to read).

M is the number of new messages in the extension’s mailbox.

# is the digit normally used by the pager service for positive disconnect.

2.In 4202-09: Delay in Dialing Digital Pager Callback Number (page 877), set the delay (0-99seconds)

that occurs just before IntraMail dials the 4202-08: Digital Pager Callback Number portion of the Mes- sage Notification callout number for a digital pager.

-Set this delay so the pager service has enough time to connect to the digital pager before sending the callback number. Your pager service may be able to help you determine the best value for this option.

-When placing a digital pager notification, the system:

-Seizes the line specified in 4112-01: Outgoing Dial 9 Group.

-Dials the user-entered notification number (in V-MAIL+ OP + N).

-Waits the 4202-09: Delay in Dialing Digital Pager Callback Number interval.

-Dials the number entered in 4202-08: Digital Pager Callback Number.

-The system assumes that the notification number will complete dialing approximately 4 seconds after line seizure. This means that, by default, the Digital Pager Callback Number will be dialed into the pager service about 13 seconds after line seizure.

2.Set up the system-wide options that apply to digital pager callouts.

1.In 4202-02: Wait Between Digital Pager Callout Attempts (page 873), set the minimum time (1-255min- utes) between unacknowledged or unanswered digital pager Message Notification callouts.

-A subscriber acknowledges a digital pager notification by logging onto their mailbox.

-After this interval expires, IntraMail will try the callout again (for up to the number of times set in 4202-06: Number of Callout Attempts (page 876).

-If the system dials the callout number and the pager service is busy, it will retry the number in one minute.

2.In 4202-07: Send Pager Callout Until Acknowledged (page 877), enter Yes to have IntraMail continue to retry a digital pager Message Notification callout until the notification is acknowledged.

-If this option is disabled (No), IntraMail will retry a digital pager Message Notification the number of times specified in 4202-06: Number of Callout Attempts (page 876).

-This option does not apply to Message Notification callouts to telephone numbers.

-A digital pager notification is considered acknowledged when the recipient logs onto the mailbox.

Other Related Features

Features

None

IntraMail Features

Security Code (page 570)

To protect their mailbox from unauthorized access, the subscriber should be sure to record a Security Code for your mailbox before enabling Message Notification.

538 IntraMail Features

DSX Software Manual

Page 568
Image 568
NEC N 1093100 software manual Unique Programming for Digital Pager Message Notification

P, N 1093100 specifications

The NEC P,N 1093092,1093092 is a high-performance electronic component renowned for its versatility and advanced technology. As part of NEC's extensive portfolio, this component is designed to meet the demanding requirements of various industries, including telecommunications, automotive, and consumer electronics.

One of the main features of the NEC P,N 1093092,1093092 is its impressive operational efficiency. This component offers low power consumption without compromising performance, making it an ideal choice for battery-operated devices and energy-sensitive applications. Its ability to function effectively at low voltage levels further enhances its appeal, allowing manufacturers to design smaller, more efficient products.

Another key characteristic of the NEC P,N 1093092,1093092 is its robust reliability and durability. With a temperature range that can withstand extreme conditions, the component ensures consistent performance even in harsh environments. This reliability is critical for applications in sectors like automotive, where components are often subject to vibrations, temperature fluctuations, and other stress factors.

Moreover, the NEC P,N 1093092,1093092 integrates advanced semiconductor technology that enables high frequency and high-speed processing capabilities. This feature makes it suitable for applications requiring fast data transmission, such as in telecommunications infrastructure and data centre operations. As technology continues to evolve, the demand for components that can handle high data rates becomes increasingly important, and the NEC P,N 1093092,1093092 is well-equipped to meet these needs.

In terms of design, the component boasts a compact form factor, which facilitates integration into various hardware configurations. This flexibility allows engineers and designers to utilize the NEC P,N 1093092,1093092 in diverse applications while maintaining space efficiency in device design.

Finally, the NEC P,N 1093092,1093092 complies with international standards, ensuring that it meets the stringent quality requirements set forth for electronic components. This compliance not only enhances the component's reliability but also simplifies the certification process for manufacturers, making it a strategic choice for projects that require adherence to industry regulations.

In summary, the NEC P,N 1093092,1093092 stands out as a cutting-edge electronic component characterized by its operational efficiency, reliability, processing capabilities, compact design, and compliance with quality standards. Its advanced features make it an essential component for modern electronic applications across various industries.