538 ◆ IntraMail Features

Message Notification

Unique Programming for Digital Pager Message Notification

1.Set up the system-wide options that apply to the digital pager callback number.

1.In 4202-08: Digital Pager Callback Number (page 877), set the Digital Pager Callback Number portion of the Message Notification callout number for a digital pager.

-This is the portion of the callout number that is appended to the pager service telephone number.

-By default, this option is X*M#, where:

X is the number of the extension that generated the notification.

*is a visual delimiter (to make the pager display easier to read).

M is the number of new messages in the extension’s mailbox.

# is the digit normally used by the pager service for positive disconnect.

2.In 4202-09: Delay in Dialing Digital Pager Callback Number (page 877), set the delay (0-99seconds)

that occurs just before IntraMail dials the 4202-08: Digital Pager Callback Number portion of the Mes- sage Notification callout number for a digital pager.

-Set this delay so the pager service has enough time to connect to the digital pager before sending the callback number. Your pager service may be able to help you determine the best value for this option.

-When placing a digital pager notification, the system:

-Seizes the line specified in 4112-01: Outgoing Dial 9 Group.

-Dials the user-entered notification number (in V-MAIL+ OP + N).

-Waits the 4202-09: Delay in Dialing Digital Pager Callback Number interval.

-Dials the number entered in 4202-08: Digital Pager Callback Number.

-The system assumes that the notification number will complete dialing approximately 4 seconds after line seizure. This means that, by default, the Digital Pager Callback Number will be dialed into the pager service about 13 seconds after line seizure.

2.Set up the system-wide options that apply to digital pager callouts.

1.In 4202-02: Wait Between Digital Pager Callout Attempts (page 873), set the minimum time (1-255min- utes) between unacknowledged or unanswered digital pager Message Notification callouts.

-A subscriber acknowledges a digital pager notification by logging onto their mailbox.

-After this interval expires, IntraMail will try the callout again (for up to the number of times set in 4202-06: Number of Callout Attempts (page 876).

-If the system dials the callout number and the pager service is busy, it will retry the number in one minute.

2.In 4202-07: Send Pager Callout Until Acknowledged (page 877), enter Yes to have IntraMail continue to retry a digital pager Message Notification callout until the notification is acknowledged.

-If this option is disabled (No), IntraMail will retry a digital pager Message Notification the number of times specified in 4202-06: Number of Callout Attempts (page 876).

-This option does not apply to Message Notification callouts to telephone numbers.

-A digital pager notification is considered acknowledged when the recipient logs onto the mailbox.

Other Related Features

Features

None

IntraMail Features

Security Code (page 570)

To protect their mailbox from unauthorized access, the subscriber should be sure to record a Security Code for your mailbox before enabling Message Notification.

538 IntraMail Features