NEC N 1093100, P 16xx-Timers, 162x-SLIAnalog Single Line Timers, Incoming, Minimum Off Hook Timer

Models: P N 1093100

1 984
Download 984 pages 47.76 Kb
Page 722
Image 722
1621-04: Maximum DP Make Timer

16xx-Timers

162x-SLI (Analog Single Line) Timers

1621-Incoming

1621-04: Maximum DP Make Timer

(Maximum Make)

Use this option to define the maximum amount of time the loop must be closed to properly decode the dial pulse digits sent from analog devices connected to SLIU PCBs. Change this value only if the connected analog devices are set to dial at a rate other than 10 PPS.

Features

• None

IntraMail Features

• None

Options

5-1275 mS

Default

100 mS

1621-05: Minimum Hookflash Timer

(Minimum Flash)

For single line PCBs, use this option to define the minimum amount of time the loop must be opened before the system starts to detect a transfer or hang up sequence. Open loop intervals shorter than the setting are ignored by the PCB.

Features

• None

IntraMail Features

• None

Options

5-1275 mS

Default

105 mS
1621-06: Maximum Hookflash Timer

(Maximum Flash)

For single line PCBs, use this option to define the maximum amount of time the loop can be opened in order for the system to detect a Transfer sequence. Open loop intervals longer than the setting are interpreted as hang up.

Features

• None

IntraMail Features

• None

Options

5-1275 mS

Default

1000 mS
1621-07: Minimum Off Hook Timer

(Minimum Off Hook)

For single line PCBs, use this option to define how long a connected analog device must remain off-hook before the system recognizes the off-hook status.

Features

• None

692 System Options: 1001-1702

DSX Software Manual

Page 722
Image 722
NEC N 1093100 16xx-Timers, 162x-SLIAnalog Single Line Timers, Incoming, 1621-04:Maximum DP Make Timer, Features, Options