Description

Use this program to adjust the timers that affect outgoing calls from analog single line telephones.

Options

1622-01: Loop Disconnect Timer

(Loop Disconnect)

Use this option to determine how long the single line PCB opens the loop to the connected analog device after the far end disconnects. This timer is used only if 1403-06: Loop Disconnect for Single Line Set (page 636) is enabled in the extension’s Class of Service.

Features

• None

IntraMail Features

• None

Options

50-12750 mS

Default

2000 mS
1622-02: Ring/MW Wait Period Time

(MW Period)

Use this option to determine the ringing sequence for the devices connected single line PCBs. Because of power consumption, it is not possible to ring all analog devices on a PCB simultaneously. Instead, the card is divided into 4 groups with two ports in each group. Ringing cycles between the 4 groups, ringing each group for this interval.

Features

• None

IntraMail Features

• None

Options

50-12750 mS

Default

750 mS