NEC P Lines, 31xx-Configuration, 310x-Setup, Description, Options, 3101-01:Line Type, Default

Models: P N 1093100

1 984
Download 984 pages 47.76 Kb
Page 839
Image 839
31xx-Configuration

31xx-Configuration

310x-Setup

3101-Type

Lines: 3101-3715

31xx-Configuration

3101x-TypeSetup

Description

Use this program to set the line circuit type, name, PBX option, and E1 signaling (for Latin America instal- lations only).

If programming multiple lines, you may find 9022-Line Copy (page 923) a handy time-saving tool.

Options

3101-01: Line Type

(Type)

Use this option to set the line’s circuit type for compatibility with the connected telco or PBX.

Features

Central Office Calls, Answering (page 74)

Central Office Calls, Placing (page 78)

Direct Inward Dialing (page 99)

Direct Inward Line (page 109)

Pulse to Tone Conversion (page 285)

T1 Lines (page 338)

Tie Lines (page 344)

IntraMail Features

• None

Options

00 for uninstalled

01 for Loop start

02 for Ground Start1

03 for DID Wink Start1

04 for DID Immediate Start1

05 for E&M Wink Start1

06 for E&M Immediate Start1

1 Requires T1 PCB.

Default

• 51

Line 3101-3715

DSX Software Manual

Line Options: 3101-3714 809
Page 839
Image 839