Description

Use this program to adjust timers that affect outgoing calls on the line (COIU) PCBs.

Options

1612-01: DP Break Timer

(Break Time)

Use this timer to set the duration of the Dial Pulse Break signal (i.e., relay open). This is the “off” time in a Dial Pulse digit. Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting may cause misdialing.

Features

Central Office Calls, Placing (page 78)

IntraMail Features

• None

Options

4-1020 mS

Default

60 mS
1612-02: DP Make Timer

(Make Time)

Use this timer to set the duration of the Dial Pulse Make signal (i.e., relay closed). This is the “on” time in a Dial Pulse digit. Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting may cause misdialing.

Features

Central Office Calls, Placing (page 78)

IntraMail Features

• None

Options

4-1020 mS

Default

40 mS
1612-03: DP Interdigit Timer

(Interdigit Time)

Use this timer to set the duration of the Dial Pulse Interdigit signal (i.e., relay open time between each digit). Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting may cause misdialing.