NEC N 1093100 16xx-Timers, 161x-COIAnalog Line Timers, Outgoing, 1612-04 PBX/Centrex Flash Timer

Models: P N 1093100

1 984
Download 984 pages 47.76 Kb
Page 716
Image 716
•100-9999 mS

16xx-Timers

161x-COI (Analog Line) Timers

1612-Outgoing

Options

100-9999 mS

Default

800 mS

1612-04: PBX/Centrex Flash Timer

(Flash 1 Time)

Use this timer to set the Flash interval. When a user flashes a line (manually or in a Speed Dial number), the system opens the line circuit for this interval. For accurate flash function, be sure to set this interval for com- patibility with the connected telco or PBX/Centrex. If you set this interval too short, the telco may not always register the flash. If too long, inadvertent disconnects may occur.

Features

Flash (page 177)

Speed Dial (page 315)

IntraMail Features

Centrex Transfer (page 460)

Options

16-4080 mS

Default

800 mS

1612-05: Flash Disconnect Timer

(Flash 2 Time)

This option is currently not implemented.

Features

• None

IntraMail Features

• None

Options

16-4080 mS

Default

2496 mS
1612-06: Ground Start Timer

(Ground Time)

Before the system can start a ground start line, the telco’s tip ground must be present for longer than this interval. Set this interval for compatibility with the connected telco or PBX/Centrex. If you set this interval too short, the system may inadvertently start a line it should not set up. If too long, the system may not start lines that are functioning normally.

Features

• None

IntraMail Features

• None

Options

16-4080 mS

Default

800 mS

686 System Options: 1001-1702

DSX Software Manual

Page 716
Image 716
NEC N 1093100 16xx-Timers, 161x-COIAnalog Line Timers, Outgoing, 1612-04 PBX/Centrex Flash Timer, Flash Disconnect Timer