NEC N 1093100 16xx-Timers, 163x-T1/E1Timers, Incoming, Receive Dial Pulse Minimum Make Timer

Models: P N 1093100

1 984
Download 984 pages 47.76 Kb
Page 726
Image 726
1631-04: Receive Dial Pulse Minimum Make Timer

16xx-Timers

163x-T1/E1 Timers

1631-Incoming

Options

4-1020 mS

Default

104 mS

1631-04: Receive Dial Pulse Minimum Make Timer

(Rx Min Make)

Use this option to set the minimum required duration of the T1 circuit receive Dial Pulse Make signal (i.e., relay closed). This is the minimum “on” time in a Dial Pulse digit. Set this timer for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting may cause misdialing.

Features

T1 Lines (page 338)

IntraMail Features

• None

Options

4-1020 mS

Default

12 mS

1631-05: Receive Dial Pulse Maximum Make Timer

(Rx Max Make)

Use this option to set the maximum allowed duration of the T1 circuit receive Dial Pulse Make signal (i.e., relay closed). This is the maximum allowed “on” time in a Dial Pulse digit. Set this timer for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make inter- val, Break interval and Interdigit interval. An improper setting may cause misdialing.

Features

T1 Lines (page 338)

IntraMail Features

• None

Options

4-1020 mS

Default

76 mS
1631-06: Receive Minimum Flash Timer

(Rx Min Flash)

Information to be provided.

Features

T1 Lines (page 338)

IntraMail Features

• None

Options

16-4080 mS

Default

640 mS
696 System Options: 1001-1702