1632-Outgoing

16xx-Timers

163x-T1/E1 Timers

1632-Outgoing

1632-Outgoing

Description

Use this program to adjust the timers that affect outgoing T1/E1 calls.

Options

1632-01: Transmit Dial Pulse Break Timer

(Tx Break Time)

Use this option to set the duration of the T1 circuit transmit Dial Pulse Break signal (i.e., relay open). This is the “off” time in a Dial Pulse digit. Set this timer for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit inter- val. An improper setting may cause misdialing.

Features

Central Office Calls, Placing (page 78)

T1 Lines (page 338)

IntraMail Features

• None

Options

4-1020 mS

Default

60 mS

1632-02: Transmit Dial Pulse Make Timer

(Tx Make Time)

Use this option to set the duration of the T1 circuit transmit Dial Pulse Make signal (i.e., relay closed). This is the “on” time in a Dial Pulse digit. Set this timer for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit inter- val. An improper setting may cause misdialing.

Features

Central Office Calls, Placing (page 78)

T1 Lines (page 338)

IntraMail Features

• None

Options

4-1020 mS

Default

40 mS

1632-03: Transmit Dial Pulse Interdigit Timer

(Tx Interdigit)

Use this option to set the duration of the T1 circuit transmit Dial Pulse Interdigit signal (i.e., relay open time between each digit). Set this timer for compatibility with the T1 service provider. Keep in mind that there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting may cause misdialing.

Features

Central Office Calls, Placing (page 78)

T1 Lines (page 338)