161x-COI (Analog Line) Timers

16xx-Timers

161x-COI (Analog Line) Timers

1611-Incoming

1611x-IncominCOI (A alog Line) Timers

Description

Use this program to adjust timers that affect incoming calls on the line (COIU) PCBs.

Options

1611-01: Minimum Ring Detect Timer

(Ring Detect)

Use this option to set the threshold for ring detection. If the ring signal is longer than this interval, the system interprets the signal as valid ringing. If the signal is equal to or shorter than this interval, the system ignores the ringing. Be sure the value you enter is compatible with the local telco. If you set this value too short, the system may detect line spikes and anomalies as ringing. If too long, the system may not properly interpret a valid ringing signal.

Features

• None

IntraMail Features

• None

Options

8-2040 mS

Default

104 mS
1611-02: Minimum Single Ring Detection Timer

(Single Ring Min)

The system uses this option to detect valid ringing signal from the connected telco or PBX. Valid single ring must be longer than this interval.

Features

• None

IntraMail Features

• None

Options

8-2040 mS

Default

1216 mS