1621-08: Dial Pulse Guard Timer

16xx-Timers

162x-SLI (Analog Single Line) Timers

1621-Incoming

IntraMail Features

• None

Options

5-1275 mS

Default

105 mS

1621-08: Dial Pulse Guard Timer

(Dial Pulse Guard)

Use this option to set the interval the single line PCB waits between dial pulse digits before attempting to detect any additional DP digits. This timer helps prevent erroneous DP dialing due to hardware stabilization.

Features

• None

IntraMail Features

• None

Options

5-1275 mS

Default

350 mS

1621-09: Off Hook Guard Time

(Off Hook Guard)

Use this option to set the interval the single line PCB waits after an analog device hangs up before accepting any additional input from the device. This timer helps prevent erroneous detection due to hardware stabilization.

Features

• None

IntraMail Features

• None

Options

5-1275 mS

Default

300 mS

System 1001-1702