NEC P 21xx-Configuration, 211x-Options, Description, Huntingand Overflow Options, Station

Models: P N 1093100

1 984
Download 984 pages 47.76 Kb
Page 775
Image 775
2115-Hunting and Overflow Options

21xx-Configuration

211x-Options

2115-Hunting and Overflow Options

2115-Hunting and Overflow Options

Description

Use this program to set the Extension Hunting and DID Intercept options for the extension (station).

If programming multiple extensions, you may find 9021-Station Copy (page 921) a handy time-saving tool.

Sample Hunt Group Programming

Circular HuntingCircular Hunting Programming (for 301, 303 and 304)
2115-01: Hunt TypeEnter the same Hunt Type for all three extensions:

 

1

= Ring No Answer Line

 

2

= Busy/Ring No Answer Line

 

3

= Busy/Ring No Answer All Calls

 

4

= Busy Line

 

 

 

2115-01: Hunt Destination

 

 

 

 

301

303

 

 

303

304

 

 

304

301 (This causes hunting to loop back to 301)

 

 

1603-01: Transfer Recall Timer

This timer sets how long an outside call waits at a busy member

 

extension. It also sets how long a call rings each member extension

 

as it cycles through the group.

 

 

1601-02: DIL No Answer Timer

This timer sets how long a DIL rings its destination member exten-

 

sion before cycling through the group.

 

 

 

Terminal HuntingTerminal Hunting Programming (for 301 and 303)

2115-01: Hunt Type

Enter the same Hunt Type for all three extensions:

 

1

= Ring No Answer Line

 

2

= Busy/Ring No Answer Line

 

3

= Busy/Ring No Answer All Calls

 

4

= Busy Line

 

 

 

2115-01: Hunt Destination

 

 

 

 

301

303

 

 

303

304

 

 

304

Press CLEAR to undefine entry. (Hunting stops at 304.)

 

 

1603-01: Transfer Recall Timer

This timer sets how long an outside call waits at a busy member

 

extension. It also sets how long a call rings each member extension

 

as it cycles through the group.

 

 

1601-02: DIL No Answer Timer

This timer sets how long a DIL rings its destination member exten-

 

sion before cycling through the group.

 

 

 

Station 2101-2501

DSX Software Manual

Station Options: 2101-2501 745

Page 775
Image 775
NEC 21xx-Configuration, 211x-Options, Description, Huntingand Overflow Options, Sample Hunt Group Programming, Station