Polycom CMA System Operations Guide

Problem

Description

Solutions

 

 

 

The MCU cannot register

Some MCU vendors register with a

Verify that the Default Gatekeeper

with the CMA system.

GRQ message instead of an RRQ

 

check box is selected in the Admin >

 

message.

 

Gatekeeper Settings > Primary

 

Some MCU vendors do not retry

 

Gatekeeper page.

 

registration after a first attempt has

Reset the MCU or MGC card to force

 

failed.

 

registration to occur.

 

 

 

 

An endpoint shows that it is

The CMA system receives the RRQ

Reboot the endpoint.

not registered to the

message, but not the LWRRQ

 

 

gatekeeper in the

message from the endpoint.

 

 

Gatekeeper Registration

The endpoint did not send a

 

 

field in the Device Status.

LWRRQ message within the offline

 

 

 

timeout period specified in the

 

 

 

Admin > Gatekeeper Settings >

 

 

 

Primary Gatekeeper page.

 

 

 

 

 

The RadVision OnLAN

The Radvision OnLAN MCU ignores

Reconfigure the Radvision OnLAN

MCU continually changes

the RCF Time to Live (TTL) field,

 

MCU to send the registration requests

state: from online to offline

which is filled in with the value that

 

in the same time period specified in

and offline to online.

the administrator specified in the

 

CMA.

 

offline timeout field in the Admin >

Add the MCU manually.

 

Gatekeeper Settings > Primary

Reboot the MCU to force registration to

 

Gatekeeper page.

 

 

occur.

 

 

 

 

 

 

Some endpoints are not

A registered H.323-only system was

Verify that the endpoint belongs to the

assigned ISDN numbers.

not assigned an ISDN number. The

 

site that has assigned ISDN number

 

system could belong to a network

 

ranges. To do so, go to Admin > Dial

 

that does not have ISDN number

 

Plan and Sites > Sites and make sure

 

ranges assigned to it.

 

the site has the correct ISDN range

 

No ISDN numbers are available to

 

specified in the ISDN Number

 

assign.

 

Assignment pane.

 

 

Verify that ISDN numbers are available

 

 

 

to assign.

 

 

Verify that the RCF message “Can’t find

 

 

 

ISDN free pool” from the gatekeeper

 

 

 

returns to the endpoint.

 

 

 

Endpoints that were

Inconsistent configuration in ISDN

Verify that the previous ISDN range was

previously registered and

number assignment has occurred.

 

changed.

auto-assigned ISDN

 

 

 

numbers are being rejected

 

 

 

when attempting to register.

 

 

 

 

 

 

 

When the CMA system is

Some endpoints do not reregister

Reboot the MCU.

restarted, some registrants

when the CMA system goes down.

 

 

that were previously online

Some MCUs do not reregister

 

 

are now offline.

 

 

automatically after two retries.

 

 

 

 

 

 

 

 

 

532

Polycom, Inc.

Page 552
Image 552