Configuration

Group

Prompt

Function Prompt

Value or

Selection

Factory Setting

Group

Prompt

Function

Prompt

Value or

Selection

Factory Setting

CONTRL

PIDSET

_______

ONE

 

SW VAL

_______

0.00

 

LSP’S

_______

ONE

 

RSPSRC

_______

NONE

 

SP TRK

_______

NONE

 

PWR UP

_______

AUTO

 

PWROUT

_______

FSAF

 

SP Hi

_______

2400

 

SP Lo

_______

0

 

ACTION

_______

REV

 

OUT Hi

_______

100

 

OUT Lo

_______

0

 

D BAND

_______

2.0

 

HYST

_______

0.5

 

FAILSF

_______

0.0

 

FSMODE

_______

NOL

 

PBorGN

_______

GAIN

 

MINRPM

_______

MIN

 

 

 

 

OPTION

AUXOUT

_______

DIS

 

ARANGE

_______

4-20

 

0 PCT

_______

0

 

100 PCT

_______

100

 

DIG IN 1

_______

NONE

 

DIG1 CMB

_______

DIS

 

DIG IN 2

_______

NONE

 

DIG2 CMB

_______

DIS

 

 

 

 

COM

COMADR

_______

Disable

 

COMSTA

_______

0

 

IRENAB

_______

Enable

 

BAUD

_______

9600

 

TX_DLY

_______

30

 

WS_FLT

_______

FP_B

 

SDENAB

_______

Enable

 

SHDTIM

_______

0

 

SDMODE

_______

Last

 

SHD_SP

_______

LSP

 

UNITS

_______

PCT

 

CSRATIO

_______

1.0

 

CSP_BI

_______

0

 

LOOPBK

_______

Disable

 

 

 

 

ALARMS

A1S1TY

 

_______

NONE

 

A1S1VA

_______

90

 

A1S1HL

_______

HIGH

 

A1S1EV

_______

BEGN

 

A1S2TY

_______

NONE

 

A1S2VA

_______

90

 

A1S2HL

_______

HIGH

 

A1S2EV

_______

BEGN

 

A2S1TY

_______

NONE

 

A2S1VA

_______

90

 

A2S1HL

_______

HIGH

 

A2S1EV

_______

BEGN

 

A2S2TY

_______

NONE

 

A2S2VA

_______

90

 

A2S2HL

_______

HIGH

 

A2S2EV

_______

BEGN

 

ALHYST

_______

0.0

 

ALARM1

_______

NOL

 

BLOCK

_______

DIS

 

DIAGAL

_______

DIS

 

 

 

 

 

DISPLY

DECMAL

_______

NONE

 

UNITS

_______

F

 

FREQ

_______

60

 

LWRDSP

_______

DIS

 

DISPLY

_______

SP

 

LNGUAG

_______

ENGL

 

TCDIAG

_______

DIS

 

 

 

 

 

Ethernet

MAC Add.

________

- -

(Accessible

IP Address

________

10.0.0.

via PIE

Subnet Mask

________

2

Tool)

 

 

 

225.22

 

 

 

 

 

Default Gate

________

5.225.0

 

 

 

To Email

________

0.0.0.0

 

SMTP Add.

________

- -

 

Alarm

________

0.0.0.0

 

Email Subj

________

NONE

 

 

 

________

- -

 

 

 

________

 

 

 

 

________

 

 

 

 

________

 

 

 

 

________

 

 

 

 

________

 

 

 

 

 

 

88

UDC2500 Universal Digital Controller Product Manual

4/07

Page 102
Image 102
Honeywell UDC2500 manual Contrl, Option, Com, Alarms, Ethernet