3.3 Configuration Procedure

Introduction

Each of the Set Up groups and their functions are pre-configured at the factory. The factory settings are shown in Table 3-4through Table 3-15that follow this procedure.

If you want to change any of these selections or values, follow the procedure in Table 3-3.This procedure tells you the keys to press to get to any Set Up group and any associated Function parameter prompt.

Procedure

ATTENTION

The prompting scrolls at a rate of 2/3 seconds when the SET UP or FUNCTION key is held in.

Also, or keys will move group prompts forward or backward at a rate twice as fast.

Table 3-3 Configuration Procedure

Step

Operation

Press

Result

1Enter Set Up

Mode

2Select any Set

Up Group

3Select a Function

Parameter

4Change the

Value or Selection

5Enter the Value

or Selection

6Exit Configuration

Setup

Setup

Function

or

Function

Lower

Display

Upper Display = SET

Lower Display = TUNING (This is the first Set Up Group title)

Sequentially displays the other Set Up group titles shown in the prompt hierarchy in Table 3-2 Configuration Prompt Hierarchy.

You can also use the or keys to scan the Set Up groups in both directions. Stop at the Set Up group title that describes the group of parameters you want to configure. Then proceed to the next step.

Upper Display = the current value or selection for the first function prompt of the selected Set Up group.

Lower Display = the first Function prompt within that Set Up group.

Sequentially displays the other function prompts of the Set Up group you have selected. Stop at the function prompt that you want to change, then proceed to the next step.

Increments or decrements the value or selection that appears for the selected function prompt. If you change the value or selection of a parameter while in Set Up mode then decide not to enter it, press M-A RESET once—the original value or selection is recalled.

Enters value or selection made into memory after another key is pressed.

Exits configuration mode and returns controller to the same state it was in immediately preceding entry into the Set Up mode. It stores any changes you have made.

If you do not press any keys for 30 seconds, the controller times out and reverts to the mode and display used prior to entry into Set Up mode.