Installation

2.5 Mounting

Physical Considerations

The controller can be mounted on either a vertical or tilted panel using the mounting kit supplied. Adequate access space must be available at the back of the panel for installation and servicing activities.

Overall dimensions and panel cutout requirements for mounting the controller are shown in Figure 2-2.

The controller’s mounting enclosure must be grounded according to CSA standard C22.2 No. 0.4 or Factory Mutual Class No. 3820 paragraph 6.1.5.

The front panel is moisture rated NEMA3 and IP55 rated and can be easily upgraded to NEMA4X and IP66.

Overall Dimensions

 

Max. panel thickness

mm

19,1

 

 

 

 

9,0

 

.75

 

inches

0,35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

92,0 + 0,8 - 0,00

3,62 + 0,03 -0,00

Panel

Cutout

92,0 + 0,8 - 0,00

3,62 + 0,03 -0,00

90,6

3,57

113,1

17,9 4,45

0,70

108,6

4,28

Figure 2-2 Mounting Dimensions (not to scale)

4/07

UDC2500 Universal Digital Controller Product Manual

15

Page 29
Image 29
Honeywell UDC2500 manual Mounting, Physical Considerations, Overall Dimensions