Power Over Ethernet Commands 1449

Default Behavior

Default limit type is None.
Command Mode
Interface Configuration
User Guidelines
This command has no user guidelines.
power inline management
Use the power inline management command in Global Config mode to set
the power management type. This command is used along with the power
inline priority command on page1451. Use the no form of this command to
set the management mode to the default.
Static and dynamic modes differ in how the available power is calculated.
Static Power Management
Available Power = Power limit of the Source - Total Allocated Power
where Total Allocated Power is calculated as the power limit configured on
the port.
Dynamic Power Management
Available Power = Power limit of the Source - Total Allocated Power
where Total Allocated Power is calculated as the amount of power consumed
by the port.
There are three power banks on a switch:
One for only the fixed power supply
One for the external power supply (EPS)
•One for both
The power limits are as follows:
Switch Fixed Only EPS Only Both
PC7024P 812W 812W 812W
2CSPC4.XCT-SWUM2XX1.book Page 1449 Monday, October 3, 2011 11:05 AM