1566 Syslog Commands
Command Mode
Global Configuration mode
User Guidelines
Up to eight syslog servers can be used. The Dell PowerConnect always uses the local7(23) facility in the syslog message. Syslog messages will not exceed 96 bytes in length. Syslog messages use the following format:
<130> JAN 01 00:00:06 0.0.0.0-1 UNKN[0x800023]: bootos.c(386) 4 %% Event(0xaaaaaaaa)
|| |||| ||||
| | | || | | | | Message
|| |||| |||
| | | || | | | Sequence Number
|| |||| ||
| | | || | | Line Number
|| |||| |
| | | || | File Name
|| ||||
| | | || Thread ID
|| |||
| | | |Component Name
|| ||
| | | Stack ID
|| |
| | Host IP Address
| Timestamp
PRI
PRI This consists of the facility code (see RFC 3164) multiplied by
8 and added to the severity. See below for more information on
severity.
Timestamp The system up time. For systems that use SNTP, this is UTC.
When time zones are enabled, local time will be used.
Host IP Address The IP address of the local system.
Stack ID The assigned stack ID. 1 is used for systems without stacki ng
capability. The top of stack is used to collect messages for the
entire stack.
2CSPC4.XCT-SWUM2XX1.book Page 1566 Monday, October 3, 2011 11:05 AM