System Management Commands 1615
show switch
Use the show switch command in User EXEC mode to display information
about units in the stack.
The show switch command shows the configuration and status of the
stacking units, including the active and standby stack management units, the
pre-configured model identifier, the plugged in model identifier, the switch
status and the current code version. If there is a stack firmware
synchronization (SFS) operation in progress, the switch status will show as
Updating Code. Both the pre-configured switch type (as set by the member
command in stack mode) and the actual connected switch type are shown.
The show switch

unitid

command shows details of the switch configuration
including the SFS last attempt status for the specified unit.
The show switch command may show an SDM Mismatch value in the Switch
Status field. This value indicates that the unit joined the stack, but is running
a different SDM template than the management unit. This status should be
temporary; the stack unit should automatically reload using the template
running on the stack manager.
Use the show supported switchtype command to display switch SIDs .
Use the show stack-ports command to display details regarding stacking links.
Use the show slot command to display details regarding slot configuration.
Use the show sdm prefer command to display the SDM template
configuration.
Syntax
show switch [chassis-mgmt | stack–member–number | stack–ports[counters
| diag] | stack–standby]
Parameter Description
Parameter Description
unitid The unit number.
chassis-mgmt Display chassis management.
2CSPC4.XCT-SWUM2XX1.book Page 1615 Monday, October 3, 2011 11:05 AM