Sflow Commands 1509
Command Mode
Global Configuration mode.
User Guidelines
An sflow destination entry must have an owner name defined in order for
polling or sampling to be configured. The last set of command parameters are
optional in the no form of the command.
Example
console(config)#sflow 1 destination owner 1 timeout
2000
console(config)#sflow 1 destination maxdatagram 500
console(config)#sflow 1 destination 30.30.30.1 560
sflow polling
Use the sflow polling command to enable a new sflow poller instance for this
data source if rcvr_idx is valid. Use the “no” form of this command to reset
poller parameters to the defaults.
Syntax
sflow

rcvr-index

polling {gigabitethernet | tengigabitethernet}
interface-list

poll-interval

no sflow

rcvr-index

polling {gigabitethernet | tengigabitethernet}

interfaces

rcvr-index
— The sFlow Receiver associated with the poller (Range: 1–8).
interface-list
— The list of interfaces to poll in unit/slot/port format.

poll-interval

— The sFlow instance polling interval. A poll interval of 0
disables counter sampling. A value of

n

means once in

n

seconds a counter
sample is generated. (Range: 0–86400).
2CSPC4.XCT-SWUM2XX1.book Page 1509 Monday, October 3, 2011 11:05 AM