Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual Specifications

Models: DVP-ES2/EX2/SS2/SA2/SX2/SE

1 702
Download 702 pages 56.54 Kb
Page 41
Image 41

 

 

 

 

 

 

 

 

 

 

2. Programming Concepts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

 

speed

 

C233~C234, 2 phase 2 input, 2

 

 

 

 

 

 

 

 

 

 

count

 

points, (*2)

 

 

 

 

 

 

 

 

 

 

up/down

 

C243~C244, 1 phase 1 input, 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

points, (*2)

 

 

 

 

 

 

 

 

 

 

 

Hard-

C245~C250, 1 phase 2 input, 6

 

 

 

 

 

 

 

 

 

 

 

ware

points, (*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C251~C254 2 phase 2 input, 4

 

 

 

 

 

 

 

 

 

 

 

 

points, (*2)

 

 

 

 

 

 

 

 

 

 

Initial step point

S0~S9, 10 points, (*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zero point return

S10~S19, 10 points (use with IST

 

 

 

 

 

 

 

 

 

Step

instruction), (*2)

 

Total 1024

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point

Latched

S20~S127, 108 points, (*2)

 

 

 

points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General

S128~S911, 784 points, (*1)

 

 

 

 

 

 

 

 

 

 

Alarm

S912~S1023, 112 points, (*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

Current value

T0~T255, 256 words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

Current value

C0~C199, 16-bit counter, 200 words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C200~C254, 32-bit counter, 55 words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D0~D407, 408 words, (*1)

 

 

 

 

 

 

 

 

Word

 

 

General

D600~D999, 400 words, (*1)

 

 

 

 

 

 

 

 

 

 

 

 

D3920~D9999, 6080 words, (*1)

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

Data

Latched

D408~D599, 192 words, (*2)

 

 

 

 

Total

 

 

 

register

D2000~D3919, 1920 words, (*2)

 

10000 points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special

D1000~D1999, 1000 words, some

 

 

 

 

 

 

 

 

 

 

 

are latched

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Index

E0~E7, F0~F7, 16 words, (*1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pointer

N

Master control loop

N0~N7, 8 points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

Pointer

 

 

P0~P255, 256 points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

Interrupt

 

 

I000/I001(X0), I100/I101(X1), I200/I201(X2),

 

 

 

 

Service

External interrupt

I300/I301(X3), I400/I401(X4), I500/I501(X5),

 

 

 

 

 

I600/I601(X6), I700/I701(X7), 8 points (01: rising-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

edge trigger

 

 

 

, 00: falling-edge trigger

 

 

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer interrupt

I602~I699, I702~I799, 2 points (Timer resolution =

 

 

 

 

 

1ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 - 9