DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

 

ES2

SS2

SA2

SX2

OFF

STOP

RUN

Attrib.

Latch

Default

Function

Ø

Ø

Ø

M

 

EX2

 

 

 

ON

RUN

STOP

 

-ed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1020

Zero flag

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1021

Borrow flag

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1022

Carry flag

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1024

COM1 monitor request

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1025*

Indicate incorrect request for

OFF

-

-

R

NO

OFF

communication

 

 

 

 

 

 

 

 

 

 

 

M1026

RAMP mode selection

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1027

PR output mode selection (8/16 bytes)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1028

Switch T64~T126 timer resulotion

OFF

-

-

R/W

NO

OFF

(10ms/100ms). ON =10ms

 

 

 

 

 

 

 

 

 

 

 

M1029*

CH0 (Y0, Y1) pulse output execution

OFF

-

-

R

NO

OFF

completed.

 

 

 

 

 

 

 

 

 

 

 

M1030*

Pulse output Y1 execution completed

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1031*

Clear all non-latched memory

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1032*

Clear all latched memory

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1033*

Output state latched at STOP

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1034*

Disable all Y outputs

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1035*

Enable X7 input point as RUN/STOP

-

-

-

R/W

YES

OFF

switch

 

 

 

 

 

 

 

 

 

 

 

M1037*

Enable 8-sets SPD function (Has to be

OFF

OFF

OFF

R/W

NO

OFF

used with D1037)

 

 

 

 

 

 

 

 

 

 

 

M1038

Switch T200~T255 timer resulotion

OFF

-

-

R/W

NO

OFF

(10ms/1ms). ON = 1ms

 

 

 

 

 

 

 

 

 

 

 

M1039*

Fix scan time

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1040

Disable step transition

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1041

Step transition start

OFF

-

OFF

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1042

Enable pulse operation

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1043

Zero return completed

OFF

-

OFF

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1044

Zero point condition

OFF

-

OFF

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1045

Disable “all output reset” function

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1046

Indicate STL status

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1047

Enable STL monitoring

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1048

Indicate alarm status

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1049

Enable alarm monitoring

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1050

Disable interruption I000 / I001

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1051

Disable interruption I100 / I101

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

2 - 18

Page 50
Image 50
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual Latch Default Function