Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual M1141 For COM2 RS-485, Modrd / Modwr

Models: DVP-ES2/EX2/SS2/SA2/SX2/SE

1 702
Download 702 pages 56.54 Kb
Page 54
Image 54

DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

 

ES2

SS2

SA2

SX2

OFF

STOP

RUN

Attrib.

Latch

Default

Function

Ø

Ø

Ø

M

 

EX2

 

 

 

ON

RUN

STOP

 

-ed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1141

For COM2 (RS-485), MODRD / MODWR

OFF

OFF

-

R

NO

OFF

/ MODRW parameter error

 

 

 

 

 

 

 

 

 

 

 

M1142

Data receiving error of VFD-A handy

OFF

OFF

-

R

NO

OFF

instructions

 

 

 

 

 

 

 

 

 

 

 

M1143*

For COM2(RS-485), ASCII/RTU mode

OFF

-

-

R/W

NO

OFF

selection (OFF: ASCII; ON: RTU)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabling the mask and alignment mark

 

 

 

 

 

 

 

 

 

 

M1156*

function on I400/I401(X4) corresponding

OFF

OFF

-

R/W

NO

OFF

 

to Y0

 

 

 

 

 

 

 

 

 

 

 

Enabling the mask and alignment mark

 

 

 

 

 

 

 

 

 

 

M1158*

function on I600/I601(X6) corresponding

OFF

OFF

-

R/W

NO

OFF

 

to Y2

 

 

 

 

 

 

 

 

 

 

M1161

8/16 bit mode (ON = 8 bit mode)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Switching between decimal integer and

 

 

 

 

 

 

 

 

 

 

M1162

binary floating point for SCLP instruction.

OFF

-

-

R/W

NO

OFF

ON: binary floating point; OFF: decimal

 

 

 

 

 

 

 

 

 

 

 

 

integer

 

 

 

 

 

 

 

 

 

 

M1167

16-bit mode for HKY input

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1168

Designating work mode of SMOV

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable the communication instruction for

 

 

 

 

 

 

 

 

 

 

M1177

Delta VFD series inverter.

OFF

-

-

R/W

NO

OFF

ON: VFD-A (Default), OFF: other models

 

 

 

 

 

 

 

 

 

 

 

 

of VFD

 

 

 

 

 

 

 

 

 

 

M1178

Enable knob VR0

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1179

Enable knob VR1

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

M1182 = ON, disable auto-mapping

 

 

 

 

 

 

 

 

 

 

 

function when connected with left-side

 

 

 

 

 

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

 

„ For SA2 /SX2 models, values of AIO

 

 

 

 

 

 

 

 

 

 

 

modules will be auto-mapped to

 

 

 

 

 

 

 

 

 

 

M1182

D9800 and above.

OFF

-

-

R/W

NO

OFF

„ If the left side is connected with a

 

 

 

 

 

communication module, additional 10

 

 

 

 

 

 

 

 

 

 

 

words will be occupied. Ex: 04AD-SL

 

 

 

 

 

 

 

 

 

 

 

+ EN01-SL + SA2, average value of

 

 

 

 

 

 

 

 

 

 

 

Ch1~Ch4 of 04AD-SL maps to

 

 

 

 

 

 

 

 

 

 

 

D9810~D9813.

 

 

 

 

 

 

 

 

 

 

 

M1183 = ON, disable auto mapping

 

 

 

 

 

 

 

 

 

 

 

function when connected with special

 

 

 

 

 

 

 

 

 

 

M1183

modules

#

-

-

R/W

NO

#

 

#: ES2/EX2: OFF; SS2/SA2/SX2: ON

 

 

 

 

 

 

 

 

 

 

 

(maps to D9900 and above)

 

 

 

 

 

 

 

 

 

 

M1190

Set Y0 high speed output as 0.01 ~

OFF

OFF

-

R/W

NO

OFF

100Hz

 

 

 

 

 

 

 

 

 

 

 

M1191

Set Y1 high speed output as 0.01 ~ 100Hz

OFF

OFF

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1192

Set Y2 high speed output as 0.01 ~ 100Hz

OFF

OFF

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1193

Set Y3 high speed output as 0.01 ~ 100Hz

OFF

OFF

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1200

C200 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1201

C201 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1202

C202 counting mode ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

2 - 22

Page 54
Image 54
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual M1141 For COM2 RS-485, Modrd / Modwr