DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

 

ES2

SS2

SA2

SX2

OFF

STOP

RUN

Attrib.

Latch

Default

Function

Ø

Ø

Ø

M

 

EX2

 

 

 

ON

RUN

STOP

 

-ed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1346*

Output clear signals when ZRN is

OFF

-

-

R/W

NO

OFF

completed

 

 

 

 

 

 

 

 

 

 

 

M1347

Auto-reset Y0 when high speed pulse

OFF

-

-

R/W

NO

OFF

output is completed

 

 

 

 

 

 

 

 

 

 

 

M1348

Auto-reset Y1 when high speed pulse

OFF

-

-

R/W

NO

OFF

output is completed

 

 

 

 

 

 

 

 

 

 

 

M1350*

Enable PLC LINK

Off

-

OFF

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1351*

Enable auto mode on PLC LINK

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1352*

Enable manual mode on PLC LINK

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable access up to 50 words through

 

 

 

 

 

 

 

 

 

 

M1353*

PLC LINK (If M1353 is ON,

OFF

-

-

R/W

YES

OFF

 

D1480~D1511 are latched devices.)

 

 

 

 

 

 

 

 

 

 

M1354*

Enable simultaneous data read/write in a

OFF

-

-

R/W

NO

OFF

polling of PLC LINK

 

 

 

 

 

 

 

 

 

 

 

M1355*

Select Slave linking mode in PLC LINK

-

-

-

R/W

YES

OFF

(ON: manual; OFF: auto-detection)

 

 

 

 

 

 

 

 

 

 

 

 

Enable station number selection function.

 

 

 

 

 

 

 

 

 

 

M1356*

When both M1353 and M1356 are ON,

-

-

-

R/W

YES

OFF

the user can specify the station number

 

 

 

 

 

 

 

 

 

 

 

 

in D1900~D1931

 

 

 

 

 

 

 

 

 

 

M1360*

Slave ID#1 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1361*

Slave ID#2 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1362*

Slave ID#3 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1363*

Slave ID#4 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1364*

Slave ID#5 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1365*

Slave ID#6 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1366*

Slave ID#7 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1367*

Slave ID#8 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1368*

Slave ID#9 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1369*

Slave ID#10 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1370*

Slave ID#11 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1371*

Slave ID#12 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1372*

Slave ID#13 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1373*

Slave ID#14 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1374*

Slave ID#15 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1375*

Slave ID#16 status on PLC LINK network

-

-

-

R/W

YES

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1376*

Indicate Slave ID#1 data interchange

OFF

-

-

R

NO

OFF

status on PLC LINK

 

 

 

 

 

 

 

 

 

 

 

M1377*

Indicate Slave ID#2 data interchange

OFF

-

-

R

NO

OFF

status on PLC LINK

 

 

 

 

 

 

 

 

 

 

 

2 - 26

Page 58
Image 58