Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual COM2RS-485 Definition of start character STX ’3A

Models: DVP-ES2/EX2/SS2/SA2/SX2/SE

1 702
Download 702 pages 56.54 Kb
Page 74
Image 74

DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

Content

ES2

SS

SA

SX

OFF

STOP

RUN

Attrib.

Latch

Default

D

EX2

2

2

2

Ø

Ø

Ø

-ed

ON

RUN

STOP

 

 

 

 

 

 

 

 

 

 

 

D1124

COM2(RS-485) Definition of start character (STX)

H’3A

-

-

R/W

NO

H’3A

 

 

 

 

 

 

 

 

 

 

 

 

D1125

COM2(RS-485) Definition of first ending character

H’0D

-

-

R/W

NO

H’0D

(ETX1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1126

COM2(RS-485) Definition of second ending

H’0A

-

-

R/W

NO

H’0A

character (ETX2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1127

Number of pulses for ramp-up operation of

0

-

-

R/W

NO

0

positioning instruction (Low word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1128

Number of pulses for ramp-up operation of

 

 

 

 

 

 

positioning instruction (High word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1129

COM2 (RS-485) Communication time-out setting

0

-

-

R/W

NO

0

(ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1130

COM2 (RS-485) Error code returning from

0

-

-

R

NO

0

Modbus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1131

Input/output percentage value of CH0(Y0,Y1)

100

-

-

R/W

NO

100

close loop control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1132

Input/output percentage value of CH1(Y2,Y3)

100

-

-

R/W

NO

100

close loop control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1133

Number of pulses for ramp-down operation of

0

-

-

R

NO

0

positioning instruction (Low word)

 

 

 

 

D1134

Number of pulses for ramp-down operation of

0

-

-

R

NO

0

positioning instruction (High word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1135*

Pulse number for masking Y2 when M1158 = ON

0

0

-

R/W

NO

0

(Low word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1136*

Pulse number for masking Y2 when M1158 = ON

0

0

-

R/W

NO

0

(High word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1137*

Address where incorrect use of operand occurs

0

0

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1140*

Number of I/O modules (max. 8)

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1142*

Number of input points (X) on DIO modules

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1143*

Number of output points (Y) on DIO modules

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1145*

Number of the connected let-side modules

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1167

The specific end word to be detected for RS

 

 

 

 

0

-

-

R/W

NO

0

instruction to execute an interruption request

 

(I140) on COM1 (RS-232).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1168

The specific end word to be detected for RS

 

 

 

 

0

-

-

R/W

NO

0

instruction to execute an interruption request

 

(I150) on COM2 (RS-485)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1169

The specific end word to be detected for RS

 

 

 

 

0

-

-

R/W

NO

0

instruction to execute an interruption request

 

(I160) on COM3 (RS-485)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1178

VR0 value

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1179

VR1 value

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1182

Index register E1

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1183

Index register F1

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1184

Index register E2

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1185

Index register F2

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1186

Index register E3

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

2 - 42

Page 74
Image 74