DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

 

ES2

SS2

SA2

SX2

OFF

STOP

RUN

Attrib.

Latch

Default

Function

Ø

Ø

Ø

M

 

EX2

 

 

 

ON

RUN

STOP

 

-ed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1233

C233 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1234

C234 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1235

C235 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1236

C236 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1237

C237 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1238

C238 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1239

C239 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1240

C240 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1241

C241 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1242

C242 counting mode (ON: count down)

OFF

-

-

R/W

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1243

C243 Reset function control. ON = R

OFF

-

-

R/W

NO

OFF

function disabled

 

 

 

 

 

 

 

 

 

 

 

M1244

C244 Reset function control. ON = R

OFF

-

-

R/W

NO

OFF

function disabled

 

 

 

 

 

 

 

 

 

 

 

M1245

C245 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1246

C246 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1247

C247 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1248

C248 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1249

C249 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1250

C250 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1251

C251 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1252

C252 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1253

C253 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1254

C254 counter monitor (ON: count down)

OFF

-

-

R

NO

OFF

 

 

 

 

 

 

 

 

 

 

 

 

M1257

Set the ramp up/down of Y0, Y2 to be “S

OFF

OFF

-

R/W

NO

OFF

curve.” ON = S curve.

 

 

 

 

 

 

 

 

 

 

 

M1260

Set up X7 as the reset signal for software

OFF

-

-

R/W

NO

OFF

counters C235 ~ C241

 

 

 

 

 

 

 

 

 

 

 

 

Enable cyclic output for table output

 

 

 

 

 

 

 

 

 

 

M1262

function of DPTPO instruction. ON =

OFF

OFF

-

R/W

NO

OFF

 

enable.

 

 

 

 

 

 

 

 

 

 

M1270

C235 counting mode (ON: falling-edge

OFF

-

-

R/W

NO

OFF

count)

 

 

 

 

 

 

 

 

 

 

 

M1271

C236 counting mode ON: falling-edge

OFF

-

-

R/W

NO

OFF

count)

 

 

 

 

 

 

 

 

 

 

 

M1272

C237 counting mode (ON: falling-edge

OFF

-

-

R/W

NO

OFF

count)

 

 

 

 

 

 

 

 

 

 

 

M1273

C238 counting mode (ON: falling-edge

OFF

-

-

R/W

NO

OFF

count)

 

 

 

 

 

 

 

 

 

 

 

2 - 24

Page 56
Image 56
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual M1233 C233 counter monitor on count down