DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

Content

ES2

SS

SA

SX

OFF

STOP

RUN

Attrib.

Latch

Default

D

EX2

2

2

2

Ø

Ø

Ø

-ed

ON

RUN

STOP

 

 

 

 

 

 

 

 

 

 

 

D1023*

Register for Storing detected pulse width (unit:

0

-

-

R/W

NO

0

0.1ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1025*

Code for communication request error

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1026*

Pulse number for masking Y0 when M1156 = ON

0

0

-

R/W

NO

0

(Low word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1027*

Pulse number for masking Y0 when M1156 = ON

0

0

-

R/W

NO

0

(High word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1028

Index register E0

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1029

Index register F0

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1030

PV of Y0 pulse output (Low word)

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1031

PV of Y0 pulse output (High word)

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1032

PV of Y1 pulse output (Low word)

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1033

PV of Y1 pulse output (High word)

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1036*

COM1 (RS-232) communication protocol

H’86

-

-

R/W

NO

H’86

 

 

 

 

 

 

 

 

 

 

 

 

D1037*

Register for setting 8-sets SPD function (has to be

0

-

-

R/W

NO

0

used with M1037)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Delay time setting for data response when PLC

 

 

 

 

 

 

 

 

 

 

 

is SLAVE in COM2 / COM3 RS-485

 

 

 

 

 

 

 

 

 

 

D1038

communication. Range: 0 ~ 10,000 (unit: 0.1ms).

-

-

-

R/W

NO

0

2. By using PLC LINK in COM2 (RS-485), D1038

 

 

 

 

 

 

 

 

 

can be set to send next communication data with

 

 

 

 

 

 

 

 

 

 

 

delay. Range: 0 ~ 10,000 (Unit: one scan cycle)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1039*

Fixed scan time (ms)

0

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1040

No. of the 1st step point which is ON.

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1041

No. of the 2nd step point which is ON

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1042

No. of the 3rd step point which is ON.

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1043

No. of the 4th step point which is ON

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1044

No. of the 5th step point which is ON.

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1045

No. of the 6th step point which is ON

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1046

No. of the 7th step point which is ON.

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1047

No. of the 8th step point which is ON

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1049

No. of alarm which is ON

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1050

Converted data for Modbus communication data

 

 

 

 

 

 

 

 

 

 

processing. PLC automatically converts the ASCII

0

-

-

R

NO

0

data in D1070~D1085 into Hex data and stores

D1055

 

 

 

 

 

 

 

 

 

 

 

the 16-bit Hex data into D1050~D1055

 

 

 

 

 

 

 

 

 

 

 

Average number of times an analog signal is input

 

 

 

 

 

 

 

 

 

 

D1062*

to the EX2/SX2 series PLC

2

-

-

R/W

YES

2

The default value is K10 for EX2 version 2.6 and

 

 

 

 

 

 

 

 

 

version 2.8.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1067*

Error code for program execution error

0

0

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1068*

Address of program execution error

0

-

-

R

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

2 - 40

Page 72
Image 72
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual D1031 PV of Y0 pulse output High word