DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

Special

Content

ES2

SS

SA

SX

OFF

STOP

RUN

Attrib.

Latch

Default

D

EX2

2

2

2

Ø

Ø

Ø

-ed

ON

RUN

STOP

 

 

 

 

 

 

 

 

 

 

 

D1253

COM3 (RS-485) communication error code (only

0

-

-

R/W

NO

0

applicable for MODRW/RS instruction)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1255*

COM3 (RS-485) PLC communication address

50

-

-

R/W

YES

1

 

 

 

 

 

 

 

 

 

 

 

 

D1256

For COM2 RS-485 MODRW instruction.

 

 

 

 

 

 

 

 

 

 

D1256~D1295 store the sent data of MODRW

 

 

 

 

0

-

-

R

NO

0

instruction. When MODRW instruction sends out

D1295

data, the data will be stored in D1256~D1295.

 

 

 

 

 

 

 

 

 

 

 

Users can check the sent data in these registers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1296

For COM2 RS-485 MODRW instruction.

 

 

 

 

 

 

 

 

 

 

D1296~D1311 store the converted hex data from

 

 

 

 

0

-

-

R

NO

0

D1070 ~ D1085 (ASCII). PLC automatically

D1311

converts the received ASCII data in D1070 ~

 

 

 

 

 

 

 

 

 

 

 

D1085 into hex data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify the number of additional pulses for

 

 

 

 

 

 

 

 

 

 

D1312*

additional pulses output and Z-phase seeking

0

0

-

R/W

NO

0

function of ZRN instruction (Has to be used with

 

 

 

 

 

 

 

 

 

M1308)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1313*

Second of RTC: 00 ~ 59

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1314*

Minute of RTC: 00 ~ 59

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1315*

Hour of RTC: 00 ~ 23

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1316*

Day of RTC: 01 ~ 31

-

-

-

R/W

YES

1

 

 

 

 

 

 

 

 

 

 

 

 

D1317*

Month of RTC: 01 ~ 12

-

-

-

R/W

YES

1

 

 

 

 

 

 

 

 

 

 

 

 

D1318*

Week of RTC: 1 ~ 7

-

-

-

R/W

YES

2

 

 

 

 

 

 

 

 

 

 

 

 

D1319*

Year of RTC: 00 ~ 99 (A.D.)

-

-

-

R/W

YES

8

 

 

 

 

 

 

 

 

 

 

 

 

D1320*

ID of the 1st right side module

0

-

-

R

NO

0

D1321*

ID of the 2nd right side module

0

-

-

R

NO

0

D1322*

ID of the 3rd right side module

0

-

-

R

NO

0

D1323*

ID of the 4th right side module

0

-

-

R

NO

0

D1324*

ID of the 5th right side module

0

-

-

R

NO

0

D1325*

ID of the 6th right side module

0

-

-

R

NO

0

D1326*

ID of the 7th right side module

0

-

-

R

NO

0

D1327*

ID of the 8th right side module

0

-

-

R

NO

0

D1336

PV of Y2 pulse output (Low word)

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1337

PV of Y2 pulse output (High word)

-

-

-

R/W

YES

0

 

 

 

 

 

 

 

 

 

 

 

 

D1338

PV of Y3 pulse output (Low word)

-

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1339

PV of Y3 pulse output (High word)

-

-

-

R/W

NO

0

 

 

 

 

 

 

 

 

 

 

 

 

D1340

Start/end frequency of the 1st group pulse output

100

-

-

R/W

NO

100

CH0 (Y0, Y1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1343

Ramp up/down time of the 1st group pulse output

100

-

-

R/W

NO

100

CH0 (Y0, Y1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1348*

When M1534 = ON, D1348 stores the ramp-down

100

-

-

R/W

NO

100

time of CH0(Y0, Y1) pulse output.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1349*

When M1535 = ON, D1349 stores the ramp-down

100

-

-

R/W

NO

100

time of CH1(Y2, Y3) pulse output.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 - 44