DVP - ES2/EX2/SS2/SA2/SX2 Operation Manual - Programming

Frequency

 

 

100KHz

 

C243 =K50000

 

 

Y0 output stops

D1340

 

 

 

 

Time

 

 

Pulse number

D1343

D1348

600ms

Specified number of output pulses: 50,500

Actual number of output pulses (D1030, D1031) = K50,560

5.Observe the results of the second execution:

a)The actual output number 50,560 – specified output number 50,500 = 60

b)60 x (1/100Hz) = 600ms (idle time)

c)600ms is an appropriate value. Therefore, set the percentage value (D1131) as K101 to complete the design.

Points to note:

1. Associated flags:

M1029 CH0 (Y0, Y1) pulse output execution completed.

M1102 CH1 (Y2, Y3) pulse output execution completed.

M1078 M1078 = ON, CH0 (Y0, Y1) pulse output pause (immediate)

M1104 M1104 = ON CH1 (Y2, Y3) pulse output pause (immediate)

M1108 CH0 (Y0, Y1) pulse output pause (ramp down). M1108 = ON during ramp down. M1110 CH1 (Y2, Y3) pulse output pause (ramp down). M1110 = ON during ramp down. M1156 Enabling the mask and alignment mark function on I400/I401(X4) corresponding

to Y0.

M1158 Enabling the mask and alignment mark function on I600/I601(X6) corresponding to Y2.

M1538 Indicating pause status of CH0 (Y0, Y1).M1538 = ON when output paused. M1540 Indicating pause status of CH1 (Y2, Y3). M1540 = ON when output paused M1305 Reverse CH0 (Y0, Y1) pulse output direction. M1305 = ON, pulse output direction

is reversed.

M1306 Reverse CH1 (Y2, Y3) pulse output direction. M1306 = ON, pulse output direction is reversed

M1347 Auto-reset CH0 (Y0, Y1) when high speed pulse output completed. M1347 will be

3 - 444

Page 560
Image 560
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual Points to note