3. Instruction Set

For A2-type only

Code

Function

Parameter

Com. Addr.

Read/Write data (Settings)

K16(H10)

Status monitor

P0-09

~ P0-13

0012H ~ 001BH

S+0 ~ S+9: Please refer to

 

(Read)

 

 

 

explanations in ASDA-A2

 

 

 

 

 

manual.

 

 

 

 

 

 

K17(H11)

Status monitor

P0-17

~ P0-21

0022H ~ 002BH

S+0 ~ S+9: Please refer to

 

selection (Write)

 

 

 

explanations in ASDA-A2

 

 

 

 

 

manual.

 

 

 

 

 

 

K18(H12)

Mapping

P0-25

~ P0-32

0032H ~ 0041H

S+0 ~ S+15: Please refer to

 

parameter (Write)

 

 

 

explanations in ASDA-A2

 

 

 

 

 

manual.

 

 

 

 

 

 

K19(H13)

JOG Operation

P4-05

 

040AH

S: Range:

 

 

 

 

 

1~5000, 4999, 4998, 0

 

 

 

 

 

 

K20(H14)

Auxiliary Function

P2-30

 

023CH

S: K1 = ON, Others = OFF

 

(Servo ON/OFF)

 

 

 

 

 

 

 

 

 

 

K21(H15)

Speed Command

P1-09

~ P1-11

0112H ~ 0117H

S+0 ~ S+5: Range:

 

(3 sets)

 

 

 

-60000~+60000

 

 

 

 

 

 

K22(H16)

Torque Command

P1-12

~ P1-14

0118H ~ 011DH

S+0 ~ S+5: Range: -300~+300

 

(3 sets)

 

 

 

 

 

 

 

 

 

 

K23(H17)

Block Data Read /

P0-35

~ P0-42

0046H~ 0055H

S+0 ~ S+15: Please refer to

 

Write Register

 

 

 

explanations in ASDA-A2

 

(for mapping

 

 

 

manual.

 

parameter )

 

 

 

 

 

 

 

 

 

 

6.For relative M flags and special D registers, please refer to explanations of API 80 RS instruction.

Program example 1: COM2 (RS-485)

1.When X0 = ON, PLC will send out communication commands by COM2 to read status of servo drive.

2.When PLC received the feedback data from ASDA, M1127 will be active and the read data will be stored in D0~D4.

3 - 4 6 3

Page 579
Image 579
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual Program example 1 COM2 RS-485