DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

 

Analog input mode

 

Upper limit value

 

Lower limit value

 

 

Current

-20 mA~+20 mA

 

+32384

 

-32384

 

 

+4 mA~+20 mA

 

+32384

 

-384

 

 

 

 

 

 

 

 

Temperature

PT100/PT1000

 

+8100

 

-1900

 

 

NI100/NI1000

 

+1800

 

-900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

 

Function

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20EX2/SX2 analog input/output mode setting (Default=H’0)

 

 

 

 

bit0~bit5: Selection between the voltage/current mode (0: Voltage; 1: Current;

 

 

 

 

Default: Voltage)

 

 

 

 

 

 

 

bit0~bit3: Analog inputs (AD0~AD3)

 

 

 

D1115

bit4~bit5: Analog outputs (DA0~DA1)

 

 

 

 

 

bit8~bit 13: Current mode

 

 

 

 

 

 

 

bit8~bit11: AD0~AD3 (0: -20 mA~20 mA; 1: 4~20 mA)

 

 

 

 

 

bit12~bit13: DA0~DA1 (0: 0~20 mA; 1: 4~20 mA)

 

 

30EX2 analog input/output mode setting (Default=H’FFFF)

The description of D1115 for 30EX2:

Bit15~12

Bit11~8

Bit7~4

 

 

 

Analog output

Analog input

Analog input

mode of DA0

mode of AD2

mode of AD1

 

 

 

Bit3~0

Analog input mode of AD0

The analog input modes for 30EX2:

 

Code

 

0x0

 

0x1

 

0x2

 

0x3

 

Description

 

Tow-wire PT100

 

Three-wire NI100

 

Two-wire PT1000

 

Two-wire NI1000

 

Code

 

0x4

 

0x5

 

0x6

 

0x7

 

Description

 

Three-wire PT100

 

Three-wire NI100

Three-wire PT1000

 

Three-wire NI1000

 

Code

 

0x8

 

0x9

 

0xA

 

0xB

 

Description

 

Voltage:

 

Voltage:

 

Voltage:

 

Current:

 

 

 

-10 V~+10 V

 

-5 V~+5 V

 

+1 V~+5 V

 

-20 mA~+20 mA

 

Code

 

0xC

 

0xD

 

0xE

 

0xF

 

Description

 

Current:

 

Reserved

 

Unused

 

 

+4 mA~+20 mA

 

 

The analog output modes for 30EX2:

 

 

 

 

 

Code

 

0x0

 

0x1

 

0x2

 

0xF

 

Description

 

Voltage:

 

Current:

 

Current:

 

Unused

 

 

-10 V~+10 V

 

+0 mA~+20 mA

 

+4 mA~+20 mA

 

 

 

 

 

 

 

 

The example of setting D1115 for 30EX2:

If the analog input mode of AD0 is the two-wire NI100, the analog input mode of AD1 is the three-wire 1000, the analog input mode of AD2 is the voltage mode (+1 V~ +5 V), and the analog output mode of DA0 is the current mode (+4 mA ~ +20 mA), the setting value in D1115 is H’2A61.