DVP - ES2/EX2/SS2/SA2/SX2/SE Operation Manual - Programming

2.Registers for setting ramp up/down time and start/end frequency: z Output Y0:

Sample time of ramp-up

Ramp-up slope

Start freq.

Y0(D1340)

Min: 6Hz

Ramp up time

Current Default: 100ms position Y0(D1343)

Pulse output frequency

End freq.

Y0 (D1340)

Min: 6Hz

Target position

Ramp down time

Default: 100ms

Y0(D1343)

zThis instruction can be used many times in user program, but only one instruction will be activated at a time. For example, if Y0 is currently activated, other instructions use Y0 won’t be executed. Therefore, instructions first activated will be first executed.

zAfter activating the instruction, all parameters cannot be modified unless instruction is OFF.

zFor associated special flags and special registers, please refer to Points to note of DDRVI instruction.