DVP - ES2/EX2/SS2/SA2/SX2 Operation Manual - Programming

2.Operand D occupies 8 consecutive word registers. The function of each device is as below:

No.

Content

Range

Format

D + 0~1

Zenith

0 ~ 90

Float

 

 

 

 

D + 2~3

Azimuth

0 ~ 360

Float

 

 

 

 

D + 4~5

Incidence

0 ~ 90

Float

 

 

 

 

D + 6

Converted DA value of Zenith

0 ~ 2000

Word

 

 

 

 

D + 7

Converted DA value of Azimuth

0 ~ 2000

Word

 

 

 

 

Note

Horizontal=0 North point=0

1LSB = 0.045

degree

1LSB = 0.18

degree

3.The execution time of SPA instruction costs up to 50ms, therefore we suggest users to execute this instruction with an interval not less than 1 sec, preventing the instruction from taking too much PLC operation time.

4.Definition of Zenith: 0° and 45°.

5.Definition of Azimuth:

N

270°

180°

45°

90°

6.The correct time of the local longitude: If we suppose that it is AM8:00:00 in Taipei, and the longitude is 121.55 degrees east, then the correct time of the local longitude in Taipei should be AM8:06:12. Please refer to API168 DTM instruction (parameter k11) for more explanation.

3 - 404

Page 520
Image 520
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual