2. Programming Concepts 2-43
Special
D Content ES2
EX2 SS
2SA
2SX
2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP Attrib. Latch
-ed Default
D1187 Index register F3 ○ ○ ○ ○ 0 - - R/W NO 0
D1188 Index register E4 ○ ○ ○ ○ 0 - - R/W NO 0
D1189 Index register F4 ○ ○ ○ ○ 0 - - R/W NO 0
D1190 Index register E5 ○ ○ ○ ○ 0 - - R/W NO 0
D1191 Index register F5 ○ ○ ○ ○ 0 - - R/W NO 0
D1192 Index register E6 ○ ○ ○ ○ 0 - - R/W NO 0
D1193 Index register F6 ○ ○ ○ ○ 0 - - R/W NO 0
D1194 Index register E7 ○ ○ ○ ○ 0 - - R/W NO 0
D1195 Index register F7 ○ ○ ○ ○ 0 - - R/W NO 0
D1220 Pulse output mode setting of CH0 (Y0, Y1) ○ ○ ○ ○ 0 - -
R/W NO 0
D1221 Pulse output mode setting of CH1 (Y2, Y3) ○ ○ ○ ○ 0 - -
R/W NO 0
D1232* Number of output pulses for CH0 (Y0, Y1) ramp-
down stop when mark sensor receives signals.
(Low word). ○ ○ ○ ○ 0 0 -- R/W NO 0
D1233* Number of output pulses for CH0 (Y0, Y1) ramp-
down stop when mark sensor receives signals.
(High word). ○ ○ ○ ○ 0 0 -- R/W NO 0
D1234* Number of output pulses for CH1 (Y2, Y3) ramp-
down stop when mark sensor receives signals.
(Low word). ○ ○ ○ ○ 0 0 -- R/W NO 0
D1235* Number of output pulses for CH2 (Y2, Y3) ramp-
down stop when mark sensor receives signals.
(High word). ○ ○ ○ ○ 0 0 -- R/W NO 0
D1240* When interupt I400/I401/I100/I101 occurs,
D1240 stores the low word of high-speed counter. ○ ○ ○ 0 0 - R
NO 0
D1241*
When interupt I400/I401/I100/I101 occurs,
D1241 stores the high Word of high-speed
counter.
○ ○ ○ ○ 0 0 - R
NO 0
D1242* When interupt I500/I501/I300/I301 occurs,
D1242 stores the low Wordof high-speed counter. ○ ○ ○ ○ 0 0 - R
NO 0
D1243* When interupt I500/I501/I300/I301 occurs, D1243
stores the high Word of high-speed counter. ○ ○ ○ ○ 0 0 - R
NO 0
D1244 Idle time (pulse number) setting of CH0 (Y0, Y1)
The function is disabled if set value0. ○ ○ ○ ○ 0 - - R/W NO 0
D1245 Idle time (pulse number) setting of CH1 (Y2, Y3)
The function is disabled if set value0. ○ ○ ○ ○ 0 - - R/W
NO 0
D1249
Set value for COM1 (RS-232) data receiving time-
out (Unit: 1ms, min. 50ms, value smaller than
50ms will be regarded as 50ms) (only applicable
for MODRW/RS instruction) In RS instruction, no
time-out setting if “0” is specified.
○ ○ ○ ○ 0 - - R/W NO 0
D1250 COM1 (RS-232) communication error code (only
applicable for MODRW/RS instruction) ○ ○ ○ ○ 0 - - R/W
NO 0
D1252
Set value for COM3 (RS-485) data receiving time-
out (Unit: 1ms, min. 50ms, value smaller than
50ms will be regarded as 50ms) (only applicable
for MODRW/RS instruction) In RS instruction, no
time-out setting if “0” is specified
50 - - R/W
NO 50