DVP - ES2/EX2/SS2/SA2/SX2 Operation Manual - Programming

K40 (40th segment)

D157, D156

D159, D158

3. Current executing segment can be monitored by D301.

X0

DPTPO D0 D300 Y0

END

4. Timing diagram:

F r eq u e nc y (Hz)

 

 

 

( D15 7,D1 56 )

 

 

 

 

....

 

 

 

 

 

 

....

( D15 9,D1 58 )

 

( D5,D4 )

 

 

 

 

 

 

 

( D1,D0 )

( D7,D6 )

 

 

 

 

 

 

 

( D3,D2 )

 

 

T i me

(S)

 

 

 

t 1

t 2

t .. ..

t 40

 

Points to note:

 

1.

Associated Flags:

 

M1029

CH0 (Y0) pulse output execution completed.

 

M1102

CH1 (Y2) pulse output execution completed

 

M1078

CH0 (Y0) pulse output pause (immediate)

 

M1104

CH1 (Y2) pulse output pause (immediate)

 

M1262

Enable cyclic output for table output function of DPTPO instruction. ON =

 

 

enable.

 

M1538

Indicating pause status of Y0

 

M1540

Indicating pause status of Y2

2.

Special registers:

 

D1030

Low word of the present value of Y0 pulse output

 

D1031

High word of the present value of Y0 pulse output

 

D1336

Low word of the present value of Y2 pulse output

 

D1337

High word of the present value of Y2 pulse output

3 - 438

Page 554
Image 554
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual Dptpo D0 D300 Y0