Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual RTU mode M1143 = on, Ff H

Models: DVP-ES2/EX2/SS2/SA2/SX2/SE

1 702
Download 702 pages 56.54 Kb
Page 461
Image 461

3. Instruction Set

Registers for received data (responding messages)

Register

Data

Descriptions

 

 

 

 

D1070 low byte

‘0’

30 H

ADR 1

 

 

 

 

D1070 high byte

‘1’

31 H

ADR 0

 

 

 

 

D1071 low byte

‘0’

30 H

CMD 1

 

 

 

 

D1071 high byte

‘5’

35H

CMD 0

 

 

 

 

D1072 low byte

‘0’

30 H

 

 

 

 

 

D1072 high byte

‘5’

35 H

 

 

 

 

Data Address

D1073 low byte

‘0’

30 H

 

 

 

 

D1073 high byte

‘0’

30 H

 

 

 

 

 

D1074 low byte

‘F’

46 H

High byte to be force ON/OFF

D1074 high byte

‘F’

46 H

 

 

 

 

 

D1075 low byte

‘0’

30H

Low byte to be force ON/OFF

 

 

 

D1075 high byte

‘0’

30 H

 

 

 

 

D1076 low byte

‘6’

36 H

LRC CHK 1

 

 

 

 

D1076 high byte

‘F’

46 H

LRC CHK 0

 

 

 

 

RTU mode (M1143 = ON)

When X0 = ON, MODRW instruction executes the function specified by Function Code 05 PLC1Ö PLC2, PLC1 sends: “01 05 0500 FF00 8C F6

PLC2 ÖPLC1, PLC1 receives: “01 05 0500 FF00 8C F6

Registers for data to be sent (sending messages)

Register

Data

Descriptions

D1256 Low byte

01 H

Address

 

 

 

D1257 Low byte

05 H

Function

 

 

 

D1258 Low byte

05 H

Data Address

 

 

D1259 Low byte

00 H

 

 

 

 

D1260 Low byte

FF H

Data content (ON = FF00H)

 

 

D1261 Low byte

00 H

 

 

 

 

D1262 Low byte

8C H

CRC CHK Low

 

 

 

D1263 Low byte

F6 H

CRC CHK High

 

 

 

Registers for received data (responding messages)

Register

Data

Descriptions

D1070 Low byte

01 H

Address

 

 

 

D1071 Low byte

05 H

Function

 

 

 

D1072 Low byte

05 H

 

 

 

Data Address

D1073 Low byte

00 H

 

 

 

3 - 3 4 5

Page 461
Image 461
Delta DVP-ES2/EX2/SS2/SA2/SX2/SE manual RTU mode M1143 = on, Ff H