2. Programming Concepts

Function Group Enable 2-speed output function of DDRVI instruction

Number M1119

Contents:

When M1119 is ON, 2-speed output function of DDRVI will be enabled.

Example: Assume that D0 (D1) is the first speed and D2(D3) is the second speed. D10(D11) is the output pulse number of the first speed and D12(D13) is the output pulse number of the second speed.

M0

 

D0

 

 

DMOV

K100000

 

 

M1

 

 

 

 

DMOV

K50000

D2

 

 

M2

K100000

D10

 

 

DMOV

 

 

M3

K50000

D12

 

 

DMOV

 

 

DMOV

K0

D1030

 

 

DMOV

K0

D1336

 

 

M0

 

 

 

 

 

SET

M1119

 

 

M1

 

 

 

 

M0

 

 

 

 

DDRVI

D10

D0

Y0

Y1

M1029

 

 

 

S0

 

 

 

 

M1

D10

D0

Y2

 

DDRVI

Y3

M1102

 

 

 

S1

 

 

 

 

 

 

 

 

END