IV ANALOG BLOCK: A/D CONVERTER

Trap vector

The A/D converter's interrupt trap-vector default address is set to 0x0C00100.

The base address of the trap table can be changed using the TTBR register (0x48134 to 0x48137).

B-IV-2-8

EPSON