DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory
3-31Release 5/6si to Release 8r
3
Figure 3-10. Fiber Optic Connections PPN to EPN1
For 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind port carrier C of the multicarrier PPN. See Figure 3-9 and Figure
3-11:
a. Install a lightwave transceiver on the c onnector at slot 1C02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect a fiber op tic cable to the transc eiver just installed.
c. Route the fiber cable to the c abinet cable tray and out of the
cabinet through the c able manager to the PDS cross-connec t
facility.
d. Connect the fiber c able to the lightguid e interface unit provid ed.
e. Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier C Slot 1C02
3. To EPN 1 Carrier A Slot 2A01
(Cabinet Stack 2)
4.Fiber Optic Cable
5. TX Connector
6. RX Connector
cydff05CJL 10319
6
RXTX
2211