DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-28Standard Reliability
5
For Either 1 or 2 Collocated Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1 (see Figure 5-5, Figure 5-6, and
Figure 5-7):
■Install a lightwave transceiver on the c able connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect 1 end of the fiber optic cable to the lightwave transc eiver,
just installed, at slot 1A01.
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
2. Behind control carrier A of EPN cabinet 2:
■Install a lightwave transceiver on c able connector a t slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
■Connect the other end of the fib er optic cab le to the lightwave
transceiver, just installed, at slot 2A01.
■Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
■At the top of the cabinet, c oil up the surplus fib er optic cab le and
attach it to the wall of the cable t ray.