DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-81Add a Control Carrier (Add Duplication)
6
Save Translations
1. Log in at the management terminal.
2. Type save translation [spe-a] disk and pr ess Enter. This command
instructs the system write all translation informa tion from memory to disk.
3. If the PPN or an EPN (where PP N Port Carrier B will be relocated ) contains
a TN750 Announcement circuit pac k, type display announcements and
press Enter.
4. If administered recorded announcements are listed, typ e list
configuration software-version and press Enter. Ch eck screen 2 to see
when the announcements were last saved. Save the c urrent
announcements by typing save announcements disk and pressing Ente r.
5. Type backup disk [spe-a] and press Enter. This instructs the system to
backup the c urrent information on disk to the system tap e.
6. Update back up tape, if required.
Label Cables
1. To make reconnecting the cables simp ler and more reliable, lab el both
ends of the connector c ables associated with the port carrier “ B” to be
removed.
Shut Down DEFINITY LAN Gateway System
If a DEFINITY LAN Gateway system resides in the control cabinet to be
upgraded, p repare to shut down the DEFINITY LAN Gateway assembly and
allow the disk to completel y spin down.
!CAUTION:
Before using this proced ure to shut down the DEFINITY LAN Gateway,
make sure that you save the system parameters if you p lan to reuse the
current system.
!WARNING:
Neglecting to shut d own a DEFINITY LAN Gateway assembly before
powering down the system c abinet where it resides c an damage the LAN
Gateway disk.
1. Log onto the DEFINITY LAN Gateway. See
DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
for the procedure to log
in.
2. When the main menu appears, select
Maintenance
.