DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-73Add IP Interface Assembly
6
3. At the command promp t, type ping

192.11.13.8

(which is the IP address of
the internal processor).
If you have connectivity, the system responds with the following
message:
Reply from 192.11.13.8: bytes=32 time<##ms TTL=###
If no response, verify the IP settings for Adap ter [1].
4. Type exit and press Enter.
The TN802B IP Interface is now installed in the DEFINITY carrier and connected
to the IP network. You can now use the Configuration Manager software
(preinstalled on the TN802B hard di sk) and DEFINITY ECS switch administration
to administer connections to other IP Trunk and ITS-E equipment.
Upgrading a TN802 V3 (or later) to a TN802B (MedPro mode)
If you have a TN802 V3 (or later) IP Interface, you must either replace it with a
TN802B circuit pack or up grade the existing TN802 ci rcuit pack to operate in
MedPro mode. Also, to operate in the Med Pro mode, the DEFINITY ECS switch
must be Release 8 or later.
NOTE:
The TN802 IP Interface must be V3 or later to upgrade to TN802B.
To upgrade the TN802 to a TN802B, you need the following hardw are:
Monitor, keyboard, and mouse to ac cess the IP Interface’s Windows NT
environment or pcANYWHERE software.
10-Mbyte SanDisk PCMCIA flashcard loaded with the MedPro
NTApp lication Install Wizard
TN802B label
The upgrade add s or modifies the following d irectories or files on your
computer’s hard d rive:
c:\dolan\*
c:\mapd\dnld\medpro.img
c:\mapd\dnld\tmp.img