DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-93Add a Control Carrier (Add Duplication)
6
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance
.
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.
Enable SPE Duplication
1. If not also duplicating switch node carriers, refer to Du plication-Related
System Paramet ers in
DEFINITY Enterprise Communications Server
Release 8 Administrator’s Guide
, to enable Switch Processing Element
(SPE) duplication.
Enable PNC Duplication
1. For a critical-reliability R8r system, typ e change system-parameters
customer-options and press Enter. Use this screen to enable the Port
Network Connectivity (PNC) duplic ation option.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using
DEFINITY Enterprise
Communications Server Release 8 Maintenance for R8r
.
2. If the Alarm Origination Activated field administration is alread y
set to y, be sure to enable Alarm Origination . Otherwise you do not need to
enable Alarm Origination (p roceed to the next section).
3. Type change system-parameters maintenance and press Enter.
The Alarm Origination Activated field was c hanged to Alarm
Origination to OSS Numbers to support more than 1 OSS.
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to enter y in both Cleared Alarm Notification and
Restart Notification fields. Press Enter.
5. Type save translation spe-a disk and press Enter .
NOTE:
The INADS Database Administrator enables Alarm Orig ination as part of
the registration process.
!WARNING:
If you do not enable Alarm Orig ination when the customer has purchased a
services contract, the switc h will not report any alarm to the TSC
automatically, causing the TSC to be unable to fulfi ll the services contract.