DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-74Add IP Interface Assembly
6
Connect the Monitor, Keyboard, and Mouse
1. Attach a VGA monitor to the VGA connector of the TN802 IP Interface
external cable assembl y.
2. Attach the keyboard to the KEYBOARD connec tor of the external cable
assembly.
3. Attach the mouse to the MOUSE connector of the external cable
assembly.
4. Plug the monitor into an AC power recep tacle and turn it on.
5. If upgrading locally, reboot Windows NT by pressing the rec essed reset
button on the faceplate (see Fi gur e 6-26) of the TN802B IP Interface until
the LCD shows a flashing MSHUT *. When the flashing stops and the
asterisk disappears (ab out 2 min), it is safe to remove the circ uit pack.
6. After the TN802B is shut down, reseat the circuit p ack to restart the
system.
7. Log in using ctrl alt del
Upgrading IP trunks (R7) to H.323 trunks
If there are existing IP trunk connections that you want to up grade to H.323 trunk
connections, do the following steps. Otherwise, g o to ‘‘Upgrade to TN802B (R8)’’
on page 6-76
To upgrade an existing IP trunk (R7) to an H.323 trunk (R8) requires first getting
IP information from the existing TN802 before upg rading the TN802 to TN802B.
1. Click on My Computer > Control Panel > Network.
2. Click the Protocols tab.
3. Select TCP/IP Protocol from the list.
4. Click the Properties option in the Network window. Write down the IP
address, subnet ad dress, and gateway ad dress shown for adapto r [2]
(see example below).
NOTE:
Do not use the addresses for adap ter [1].