DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-85Critical Reliability
5
12. Connect the loose end of the TDM/LAN cab le (between the “A” and “D”
carriers) to the pin-field b lock marked “TDM” on the rig ht side of the “A”
carrier (see Figure 5-26 and Table 5-15). The other end remained
connected to the “ D” carrier when the old c arrier was removed.
13. Connect the loose end of the TDM/LAN cab le (between the “B” and “C”
carriers) to the pin-field b lock marked “TDM” on the rig ht side of the “B”
carrier. The other end remained conn ected to the “C” c arrier when the old
carrier was removed.
14. Install the TDM/LAN cable between the “ A” and “B” c arriers. The cable is
connected to the “ A” and “B” c arriers at the pin-field bloc ks marked
“TDM” on the left side of eac h carrier.
15. On port carrier J58890BB-1, c onnect the TDM cable or the TDM
terminator to Slot 02. On port carriers J58890BB -2 and J58890BB-3,
connect the TDM cables or th e TDM terminator to Slot 01. If the port
carrier has J58890BB-1
and
J58890BB-2 printed on it, treat it as a
J58890BB-1.
Table 5-15. TDM/LAN Connections
"J" Number Carrier Type LHS Slot RHS Slot
J58890BB-1 Port 21 02
J58890BB-2 Port 21 01
J58890BB-3 Port 21 01
J58890AF EPN Control “A” 21 02