DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-90Add a Control Carrier (Add Duplication)
6
10. Connect the loose end of the TDM/LAN cab le (between the “C” and “B”
carriers) to the pin-field b lock marked “TDM/LAN” on t he right side of the
“B” carrier (See Figure 6-31 and Table 6-8). The other end remained
connected to the “ C” carrier when the old c arrier was removed.
11. Connect the loose end of the TDM/LAN cab le (between the “A” and “B”
carriers) to the pin-field b lock marked “TDM/LAN” on t he left side of the
“B” carrier (See Figure 6-31 and Table 6-8). The other end remained
connected to the “ A” carrier when the old ca rrier was removed.
12. Install the alarm duplic ation cable (H600-198 G1) between c arriers “B”
and “A.” Connect the cable to the “ICCA” pin -field block (to the right of the
pin-field bloc k for slot “00”) of both carriers. See Figure 6-32. Connec t the
“UAK” (upper) connec tor to carrier “B,” and connect the “ LAK” (lower)
connector to carrier “ A.”
!CAUTION:
While installing the ICC cable c onnectors, be careful not to bend any backplane p ins. Double check eac h connection to verify that the pins are straight.
NOTE:
With a connector in each hand , flex the wires within the cable’s
sheath to form a usable C-shaped cable.
13. Install the ICCC cable (H600-182 G1) between carriers “B” and “ A.”
Connect the cable to the “ ICCC” pin-field b lock (behind slot “01” ) of both
carriers. See Figure 6-32.
14. Install the duplication c able (WP91954 L1) between carriers “B” and “A.”
Connect the cable to the “ ICCD” pin-field b lock (behind slot “02” ) of both
carriers. See Figure 6-32.
NOTE:
The duplication cab le’s connectors are keyed to e nsure proper
positioning on the pin- field block.
Table 6-8. TDM/LAN Connections
“J” Number Carrier Type LHS Slot RHS Slot
J58890BB L1 Port 21 02
J58890BB L2 Port 21 01
J58890BB L3 Port 21 01
J58890AP Control 21 02