DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-20Upgrade the software and hardware
2
Enable Customer Options and Alarm Origination
to INADS
1. Get the DOSS order number of th e u pgrade from the project manager and
ask the regional Customer Software Administration to com plete the steps
in the shaded box. See ‘‘Where to Call for Technical Suppor t’’ on page -xx
for telephone numbers.
NOTE:
As part of the system registration p rocess, the INADS Database
Administrator enables Alarm O rigination.
2. When administration is completed , log in as craft.
Check SPE status (H/C only)
1. Type status SPE and press Enter. Wait until
The Standby Refreshed field s hows yes
The Standby Shadowing field s hows on
The Standby Handshake field s hows up
Save Translations
1. Type save translation and press Enter to copy up graded translati ons to
the system disk, which takes ab out 2 minutes.
"init" login administration:
1. Log in as init.
2. Type change system-parameters customer-options and press Enter
to verify that the customer options are p roperly set.
3. Go to screen 6, QSIG Optional Features, and set the Basic Call
Setup field to y if the customer was using Supplementary Services
Protocol b or d on an ISDN-PRI trunk group before the up grade.
4. Type change system-parameters offer-options and press Enter.
5. If the Activate Offer field is n, set it to y and press Tab. A warning
message lets you know whether you need to save translations and
reboot to make the change p ermanent.
6. Press Enter to effect the ch anges or Cancel if there were no chang es.
7. Contact the requester when done .