DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory
3-25Release 5/6si to Release 8r
3
Figure 3-7. Typical Fiber Optic Connections
For 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind port carrier B of the multicarrier PPN. See Figure 3-6 and Figure
3-8:
a. Install a lightwave transceiver on the c onnector at slot 1B02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect a fiber op tic cable to the transc eiver just installed.
c. Route the cable to the cab inet cable tray and out of the cabinet
through the cable manag er to the PDS cross-connect facility.
d. Connect the fiber c able to the lightguid e interface unit provid ed.
e. Carefully attach the fiber optic cable (with ca ble ties) to the wall of
the cable tray at the built- in cable tie positions.
Figure Notes
1. Lightwave Transceiver
2. To PPN Carrier B Slot 1B02
3. To EPN 1 Carrier A Slot 2A01
(Cabinet Stack 2)
4.Fiber Optic Cable
5. TX Connector
6. RX Connector
cydff05CJL 10319
6
RXTX
2211