DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Fiber Link Administration
A-17Administer Fiber Links
A
DS1 Converter Complex Administration for T1 TN1654 Circuit Packs.
Screen 6-5. Fiber Link Administration form for T1 TN1654 Circuit Pack (DS1 Converter
Complex Administration) (page 2 of 3)
The following unique fields d isplay when administering a T1 TN1654 DS1
Converter.
■Bit Rate — Displays when the DS1 Converter circuit p ack is TN1654.
Enter either 1.544 for domestic T1 operation or 2.048 for inter national E1
operation.
NOTE:
Since one bit rate applies fo r all facilities within the same DS1
Converter complex, the Bit Rate field displays only und er
Facil ity A.
■Facility Startup Idle Code— Displays when the DS1 Converter circu it
pack is TN1654. Enter 8 digits, each d igit must be 0 or 1. The second digit
must be 1. Default is 11101000. You can administer this field on a per
circuit pack b asis. This is the idle cod e used when a TN1654 first
establishes a link on a T1/E1 facility. The initial idle code used by the
TN1654 is overwritten by the center stage sw itch to an “all ones” p attern
once framing is establis hed on that T1/E1 facility.
■Framing Mode — For TN1654 with 1.544 Mbps Bit Rate, this is a
display-only field.
add fiber-link next Page 2 of 3
FIBER LINK ADMINISTRATION
A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01
DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654
DS1 CONVERTER FACILITIES
ABC D
Facility Installed? yes yes no no
Bit Rate: 1.544
Facility Startup Idle Code: 11101000
Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs
Framing Mode:
DS1CONV-1 Line Compensation: 1 1 1 1
DS1CONV-2 Line Compensation: 1 1 1 1
Facility A Circuit ID: 09876543
Facility B Circuit ID: 234567889