DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-71Add IP Interface Assembly
6
If administered remotely through p cANYWHERE:
21. Click on the pcANYWHERE Restart Host Computer button on the toolbar
to restart the computer.
If administered locally on a moni tor, keyboard, and mouse:
21. Click Yes in the d ialog box to restart the co mputer.
!WARNING:

When connected remotely via p cANYWHERE, only use the pcANYWHERE

Restart Host Computer button on the toolba r to restart Windows NT.

Check Network Services
When the server restarts, make sure that the required network servic es have
started correctly. If you see an error dialog box, then the network services d id not
start correctly. Also, check the NT Event Log.
1. Click on My Computer > Control Panel > Network > Services. Make
sure that the following services are listed :
Computer Browser
Microsoft Internet Information Server 2.0
NetBIOS Interface
RPC Configuration
Server
Workstation
2. Click the Protocols tab, and examine the Network Protocols. TCP/IP
protocol should b e the only one listed.
3. Click OK.
Test the External Connection to the LAN
To test the external IP connections, ping the IP Interface server an d ping a known
computer connec ted to your network.
1. Click Start > Programs > Command Prompt.
2. Type ping
nnn.nnn.nnn.nnn
(which is your IP address).
If everything is config ured correctly, the system responds wit h the
following message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time<##ms
TTL=###
If no response, verify the IP-address information and check the
connectivity, including the cabling.